Lex-Loc Male Edison Plug 50 Pack

$9.68
Part No: X515POEM Lex-Loc Male Edison Plug 15 Amp, 125 VAC, 2 Pole, 3 Wire, NEMA 5-15 LexLoc Edison Plug.

Cage clamp terminations cannot loosen, eliminating the main cause of device failure. Does not require tools; simply finger-open and close the terminals. Two fast-travel assembly screws save labor. All-black color blends into scenery. External cord clamp provides enhanced strain relief for a wide range of cord sizes.

DESIGNED FOR DURABILITY
Lex-Locâ„¢ devices meet or exceed Hospital Grade U.S. tests. Devices conform to U.S. Standards for hospital equipment, #498 and #544, including:
-Abrupt plug removal (parallel to wall) test
-Ground contact temperature test
-Ground resistance test
-Grounding contact overstress test
-Assembly security test
-Mold stress relief test
-Crush test
-Cord grip strain relief tests
-Static cord pull test
-Rotary cord pull test
-Impact resistance test
-Mechanical drop test

CONSTRUCTION
Housing and Body: Nylon - Tough and resistant to a wide range of chemicals. UL Recognized for 125°C continuous use. UL 94V-2 Flammability Index. Beveled design to resist snagging. Blades and Contacts: Solid brass for excellent conductivity Terminal Cover: Clear polycarbonate - terminals visible Assembly Screws: Two U-drive combination slot/crosshead

MECHANICAL
Accommodates 18/3 SJ through 10/3 S cable
Cord Accommodation (with inserts): .300''- .430''
Cord Accommodation (inserts removed): >.430''- .655''

ELECTRICAL
Dielectric Withstand Voltage: >3,000V
Heat Rise: Maximum 30°C after 100 cycles at 150% of rated current
Current Interrupting: Yes

U.L. Listed File E57672
C.S.A. Certified File LR81290


Quantity:
Add To Cart
Part No: X515POEM Lex-Loc Male Edison Plug 15 Amp, 125 VAC, 2 Pole, 3 Wire, NEMA 5-15 LexLoc Edison Plug.

Cage clamp terminations cannot loosen, eliminating the main cause of device failure. Does not require tools; simply finger-open and close the terminals. Two fast-travel assembly screws save labor. All-black color blends into scenery. External cord clamp provides enhanced strain relief for a wide range of cord sizes.

DESIGNED FOR DURABILITY
Lex-Locâ„¢ devices meet or exceed Hospital Grade U.S. tests. Devices conform to U.S. Standards for hospital equipment, #498 and #544, including:
-Abrupt plug removal (parallel to wall) test
-Ground contact temperature test
-Ground resistance test
-Grounding contact overstress test
-Assembly security test
-Mold stress relief test
-Crush test
-Cord grip strain relief tests
-Static cord pull test
-Rotary cord pull test
-Impact resistance test
-Mechanical drop test

CONSTRUCTION
Housing and Body: Nylon - Tough and resistant to a wide range of chemicals. UL Recognized for 125°C continuous use. UL 94V-2 Flammability Index. Beveled design to resist snagging. Blades and Contacts: Solid brass for excellent conductivity Terminal Cover: Clear polycarbonate - terminals visible Assembly Screws: Two U-drive combination slot/crosshead

MECHANICAL
Accommodates 18/3 SJ through 10/3 S cable
Cord Accommodation (with inserts): .300''- .430''
Cord Accommodation (inserts removed): >.430''- .655''

ELECTRICAL
Dielectric Withstand Voltage: >3,000V
Heat Rise: Maximum 30°C after 100 cycles at 150% of rated current
Current Interrupting: Yes

U.L. Listed File E57672
C.S.A. Certified File LR81290


Part No: X515POEM Lex-Loc Male Edison Plug 15 Amp, 125 VAC, 2 Pole, 3 Wire, NEMA 5-15 LexLoc Edison Plug.

Cage clamp terminations cannot loosen, eliminating the main cause of device failure. Does not require tools; simply finger-open and close the terminals. Two fast-travel assembly screws save labor. All-black color blends into scenery. External cord clamp provides enhanced strain relief for a wide range of cord sizes.

DESIGNED FOR DURABILITY
Lex-Locâ„¢ devices meet or exceed Hospital Grade U.S. tests. Devices conform to U.S. Standards for hospital equipment, #498 and #544, including:
-Abrupt plug removal (parallel to wall) test
-Ground contact temperature test
-Ground resistance test
-Grounding contact overstress test
-Assembly security test
-Mold stress relief test
-Crush test
-Cord grip strain relief tests
-Static cord pull test
-Rotary cord pull test
-Impact resistance test
-Mechanical drop test

CONSTRUCTION
Housing and Body: Nylon - Tough and resistant to a wide range of chemicals. UL Recognized for 125°C continuous use. UL 94V-2 Flammability Index. Beveled design to resist snagging. Blades and Contacts: Solid brass for excellent conductivity Terminal Cover: Clear polycarbonate - terminals visible Assembly Screws: Two U-drive combination slot/crosshead

MECHANICAL
Accommodates 18/3 SJ through 10/3 S cable
Cord Accommodation (with inserts): .300''- .430''
Cord Accommodation (inserts removed): >.430''- .655''

ELECTRICAL
Dielectric Withstand Voltage: >3,000V
Heat Rise: Maximum 30°C after 100 cycles at 150% of rated current
Current Interrupting: Yes

U.L. Listed File E57672
C.S.A. Certified File LR81290


Lex Cam-Type 16 Series Male Inline Connector
Sale Price:$25.99 Original Price:$29.55
sale
Lex 100A 120V Male inline Connector
$75.00
Lex 100A 240V Female inline connector (Yellow Cover)
$75.00
Lex Cam-Type 16 Series Female Double Set Screw Panel Mount Connector
Sale Price:$40.99 Original Price:$51.99
sale
Lex 100A 120V Female inline Connector
Sale Price:$71.00 Original Price:$75.00
sale